diff --git a/scl-extension/src/main/resources/xsd/SCL_CoMPAS.xsd b/scl-extension/src/main/resources/xsd/SCL_CoMPAS.xsd index 7c1be819..afe64752 100644 --- a/scl-extension/src/main/resources/xsd/SCL_CoMPAS.xsd +++ b/scl-extension/src/main/resources/xsd/SCL_CoMPAS.xsd @@ -22,6 +22,7 @@ SPDX-License-Identifier: Apache-2.0 Version 1.8 Release 2024/05/16 Version 1.9 Release 2024/06/25 Version 2.0 Release 2026/02/04 + Version 2.1 Release 2026/09/08 @@ -110,185 +111,6 @@ SPDX-License-Identifier: Apache-2.0 - - - - - Define whether the Flow between two LDevice belonging to two ICDs with-in two System Version (identical or different) are qualified (ACTIVE), not working (INACTIVE) or untested (UNTESTED) - The INACTIVE or UNTESTED Flows cannot be used. - - - - - - - - - - - - - Define whether the LDevice belonging to one ICD with-in one System Version are qualified (ACTIVE), not working (INACTIVE) or untested (UNTESTED) - The INACTIVE or UNTESTED LDevice cannot be used. - - - - - - - - - - - - - Define whether the IED with-in one System Version is used as NOMINAL or BACKUP IED - "A" defines the nominal IED instance when a redundancy IED exists - "B" defines the backup IED instance when a nominal IED exists - "C" defines the second backup IED instance when a nominal and backup IEDs exist (used for teleaction) - "D" defines the third backup IED instance when a nominal, backup and second backup IEDs exist (used for teleaction) - "None" is used when there is no backup IED instance - - - - - - - - - - - - - - - Define whether the Flow is limited to the Bay(refering to the physical one or cubicles) to which belong the IED (BAY_INTERNAL) or only going outside the BAY (BAY_EXTERNAL) - - - - - - - - - - - - Define if a bay Direction is Up or Down regarding the busbarsections - For controlbusbar bay the N/A is used to refer that there is no graphical object for this bay. - - - - - - - - - - - - Define the specific Compas attributes linked to the Bay. - The UUID defines the unique ID of the Bay - The Main and Long Labels are label of the bay - MainLabel and Version identify uniquely the instanciated Bay as the UUID - The BayCodif is identifying the bay kind (i.e LI for line feeder) - The NumBay is the bay number for a given baykind. It's used for the dataflow binding in the FlowSourceBayNum - The BayCount is the bay number whatever the kind. As a consequence it's unique accross the substation - - - - - - - - - - - - - - - - - Define specific Compas attributes to identify uniquely one ICD file with-in a SystemVersion for a given IEDType, IEDredundancy and IEDinstance. - The UUID of this combinaison is defined by the ICDSystemVersionUUID. - The ICDSystemVersionUUID is unique within the whole SystemVersion and identify a given instance of a hardware - The IEDType defines the set of LDevice which are supported by a given type of IED hardware - The IEDSubstationinstance identify with a number the IED. This number is unique accross the substation - The IEDName is used to replace the /IED@name = ICDSystemVersionUUID of the IED which is defined in the STDfile by the /IED@name = IEDName of this private - The VendorName, IEDmodel, hwRev, swRev, headerId, headerVersion, headerRevision are issued from the ICD file thanks to the LPHD0.PhyNam DA and the Header attributes of the ICD - The bayLabel defines the bay name where the IED is located; it can be different from the bay name where the Function and LDevice are associated to - This private is intended to be used in the STD file (/IED level) and SSD (/LNode level) - - - - - - - - - - - - - - - - - - - - - - Identify the SystemVersion to which the functional Bay and IED belongs to. This Private can be used in /Bay in substation and in the /IED - The MainSystemVersion is common to all the bays of the substation (i.e. XX = 01 and YY = 01 => 01.01) XX refers to a technical environment YY refers to functional perimeter so to a set of specification - The MinorSystemVersion is specific for each bay of the substation (i.e. 01.02.03 for the second line feeder bay with the third IED combinatory) - - - - - - - - - - Identifies the Function from the user specific catalog of function - - - - - - - - - - Identifies the LDevice from the user specific catalog of LDevice - - - - - - - - - - Describe the connectivity node and layout order for a given Bay;can be multiple instanciated in case of bay which is connected to multiple nodes or the busbarcontrol bay - The private is intended to be defined at /Bay leel - Same logic applies for the : - - Node and FLOWSourceBayNode - - NodeOrder and FlowSourceNumBayBusBarSectionOrder - BusBarSectionOrder is defined once only in the BusBarControlBay to define the order of busbarsections within a given busbar - The Direction defines whether the bay feeder shall be represented graphically up or down - The ConnectivityNodeName defines the link beetween the bay and electrical node to which it's connected to - - - - - - - - - @@ -320,54 +142,4 @@ SPDX-License-Identifier: Apache-2.0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - \ No newline at end of file +