Signal auto downsampling is not applied as configured: hidden 5x threshold, settings changes ignored for unselected signals #455
Signal auto downsampling (Settings > Visualization > Signals, enabled by default with a maximum of 100,000 points) does not behave as configured:
Signals between 100,000 and 500,000 points are drawn in full. Downsampling only starts above 5 times the configured maximum number of points, which is not documented anywhere.
Changing Use auto downsampling or Downsampling max points (or the line width settings) only updates the curves of the selected signals. The other curves keep the previous setting, even after they are selected again.
The documentation and the settings dialog give 10,000 as the default maximum number of points, whereas the actual default value is 100,000.
Measured in DataLab (number of points drawn, CurveItem.dataSize()):
Step
150k pts
300k pts
600k pts
2M pts
Creation (max 100,000)
150,000
300,000
100,000
100,000
Max set to 10,000 (2M signal selected)
150,000
300,000
100,000
10,000
Then each signal selected
150,000
300,000
100,000
10,000
Root causes
apply_downsampling (SigimaX) only downsamples when nbpoints > 5 * maxpoints, and its factor nbpoints // maxpoints may draw more than maxpoints points (599,999 points are drawn as 120,000 points).
Since v1.0.0 (a9b540f), a change of the sig_autodownsampling* and sig_linewidth* settings calls manual_refresh(), which only refreshes the selected objects. Before, all existing plot items were updated. A later selection change does not update the items either (update_items=False).
datalab/gui/settings.py and doc/features/common/settings.rst still give 10,000 as the default value.
Proposed changes
SigimaX: downsample as soon as a signal has more points than the configured maximum, with a factor such that at most this number of points is drawn.
DataLab: apply signal display settings changes to all existing curves, not only to the selected ones.
DataLab: show and document the actual default value (100,000), and state that downsampling only affects the display (data and processing are unchanged).
Activity
PierreRaybaut commentedon Oct 29, 2026
Fixed by #456 (merged into develop, will be released in DataLab 1.4.0), with DataLab-Platform/SigimaX#31. Follow-up: PlotPyStack/PlotPy#85 (min/max downsampling).