The instrument window recomputed its axes only when the X axis changed (size or bounds of the signals), so a new InstrumentFrame.value_range with the same time base was ignored. In the oscilloscope simulator, changing a channel scale or offset left the Y axis on the previous setting.

Now, when only the value range changes, the Y axis follows it (or is autoscaled alone when the range becomes None), and the user's zoom along X is kept, as when changing V/div on a real oscilloscope. A change of the X axis still rescales both axes.

Tests

  • plugin_tools_app_test.py now zooms along X, then renders a frame with the same X and a new range: Y follows and the X zoom is kept; without a range, Y is autoscaled alone; a new X axis is rescaled. This test fails on the previous code (Y stayed at (-2, 2) instead of (-5, 5)).
  • Plugin feature and backbone tests: 196 passed (the 3 plugin_generator_unit_test.py failures are environmental: sigimax missing in a subprocess).

DataLab-Web is not affected: a browser probe on the unchanged code showed that, after a user zoom, the Y axis follows a new value range and the X zoom is kept.

Assisted-by: Claude Opus 5.5

@PierreRaybaut
PierreRaybaut merged commit abe255b into develop Oct 9, 2026
6 checks passed
@PierreRaybaut
PierreRaybaut deleted the fix/instrument-value-range branch October 9, 2026 07:38
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant