The GPU zones have one passive trip, so power_allocator runs continuously and can limit CPU power while GPU temperatures are low. Add an earlier passive trip to start control near the existing target. The 100 C switch-on point is provisional and needs thermal review. Generated-by: LLM Assisted-by: LLM Signed-off-by: Michal S. <me@mchal.lol>
notmysegv
marked this pull request as ready for review
November 2, 2026 21:25
notmysegv
force-pushed
the
codex/j614-j616-gpu-thermal
branch
from
November 3, 2026 01:23
2bffe0c to
ff1d3ac
Compare
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Problem
The J614s/J616s GPU zones each have one passive trip at 101°C. With only one
passive trip,
power_allocatortreats it as the target and runs continuously.On a J614s, a trace showed GPU-zone CPU cooling while GPU sensors were around
57–64°C, contrary to the intended GPU-limit backstop described in #511.
Proposal
Add a separate 100°C switch-on passive trip before each existing 101°C target.
The existing target cooling maps and 118°C critical trips are unchanged.
The 100°C choice is provisional: it starts the controller 1°C before the
GPU firmware limit, but it and the estimated sustainable power need review.
The controller's PID gains change with the separation between the trips. With
the default estimated proportional gain and a 1°C gap, the proportional term
alone reduces the sustainable-power budget to approximately zero at 1°C
above the target; accumulated negative integral error can reduce it sooner.
This may result in maximum CPU cooling near 102°C, and needs review before
the threshold or controller tuning is accepted.
The running J614s estimates sustainable power as 4,620 mW: the CPU cooling
devices' minimum-frequency energy-model powers, summed over the three CPU
policies. It is not a measurement with the GPU held at 101°C. At the proposed
100°C switch-on the default feed-forward and proportional terms initially
allow about 13.86 W combined, falling toward 4.62 W at the target before
integral effects. The actual per-cluster result also depends on demand and
load normalization; a replacement budget needs joint CPU/GPU evidence.
Changing the budget alone scales the default proportional gain with it, so
with the same 1°C gap the proportional budget still approaches zero 1°C above
target; a longer integral time constant does not change that proportional zero.
Aurora's fanless J700
and J613
use two trips with board-measured budgets and a 37°C gap; J700's source notes
oscillation with higher gains. Those results are useful precedent for
measurement, but their values are not a J614s/J616s tune.
The board-tree comment describes shedding CPU power from 101°C. This draft
would start at 100°C. A 101/102°C switch/target pair would match that onset
but move the governor target above the firmware's 101°C limit; a wider gap
below 101°C would start shedding earlier. Neither alternative has been
qualified. Maintainer guidance on the intended onset and target would help
choose between these tradeoffs.
On the tested J614s, the running driver reports 25G83 firmware. The
25G83 initialization code
writes a documented 101°C fast-die target and 96°C release. These are
driver-supplied constants, not an independent J614s firmware-limit measurement;
the firmware release value is not equivalent to IPA's switch-on temperature.
This is based on #795, whose shared device tree covers both machines. Please
do not merge on the basis of the tests below alone.
Testing on J614s
only the seven new trip nodes. The J614s candidate booted with both passive
trips and the original critical trip on each GPU zone.
in 74 samples; a complete trace showed no GPU-attributed CPU limit events.
The earlier one-trip comparison had nonzero P0 cooling in 70 of 74 samples.
and P-core workload crossed the switch-on temperature. P0 cooling was zero
below it and entered nonzero states above it; after restoring the original
trips during the workload it returned to zero. GPU rendering and compute
readback checks passed. Peak CPU/GPU/TVMR-or-TVMr readings were
81.25/55.82/82.04°C. All trip values were restored afterward.
with no GPU-attributed CPU limit events. The hottest GPU zone reached
65.59°C; the hotter of TVMR/TVMr reached 101.28°C. This did not exercise
the actual 100°C switch-on point.
1.1–2.6°C above the target during a P-core workload. GPU0 requested the
maximum cooling state on both P-clusters (18/18) and E-cluster (6/6). The
sensor did not cool through the switch-on trip during the test. This is a
lowered-trip controller test, not a measurement at 101–104°C, but warrants
particular review of the candidate's above-target aggressiveness.
same lowered target. At overlapping GPU temperatures of 49.131–49.557°C,
P0 reached maximum cooling in 39/59 workload samples, versus 57/57 in the
earlier 1°C-gap run. The wider gap delayed maximum cooling but did not
eliminate it; these separate short runs do not qualify a production setting.
The original trips, governor and gains were restored.
Still needed
including the sharper PID response and potential switching around 100°C.
the lowered-trip experiment does not establish hardware temperature limits.
response or performance.