Notes a live finding on indoor_temperature and the temp_follow_me encoding: with Follow Me active, the C0 readback is a whole degree, but the unit regulates on the half-degree value sent in 0x41 body[5].

Evidence: step test 2026-10-26 (source stepped 22.0 / 21.5 / 21.0 / 20.0 / 22.0 / 23.0 °C). A 21.5 °C source moved the control error by 0.5 K while the readback showed 22.0 °C. All 4266 one-minute samples under Follow Me from 2026-10-22 to 2026-10-26 were whole degrees.

Notes only, no decode change. Core tests and the excluded-script runner pass.

🤖 Generated with Claude Code

…half step

A live step test on 2026-10-26 showed the C0 indoor_temperature readback
is a whole degree while Follow Me is active, but a 21.5 °C source moved
the control error by 0.5 K. Note it on indoor_temperature and on the
temp_follow_me encoding so nobody infers the regulated value from the
readback.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@fabcoded
fabcoded merged commit d182e8a into main Oct 27, 2026
8 checks passed
@fabcoded
fabcoded deleted the docs/follow-me-readback-rounding branch October 27, 2026 22:08
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant