Error-state EKF fusing a 200 Hz IMU with 5 Hz position fixes for a simulated quadrotor, validated against dead reckoning and a linear KF (NEES-consistent)

Resources

Stars

2 stars

Watchers

0 watching

Forks

Latest commit

 

History

18 Commits

Folders and files

Repository files navigation

dronefuse

Sensor fusion for a simulated quadrotor: an error-state EKF that fuses a 200 Hz IMU with 5 Hz position fixes, validated against dead reckoning and a linear Kalman filter.

Truth vs three estimators on a figure-eight, with a 5 s position-fix dropout at 30-35 s

Figure-eight, 60 s, seed 0, position fixes dropped between 30 s and 35 s (grey band):

Estimator Pos RMSE [m] Vel RMSE [m/s] Max pos err [m] Mean NEES (ideal 6) NEES in 95 % bounds
DR 139.205 5.479 293.93 n/a n/a
KF 1.200 0.880 8.11 3.01 83.0 %
EKF 0.229 0.151 0.74 5.58 93.7 %
  • The EKF's position error is about 600× lower than dead reckoning and 5× lower than the linear KF.
  • Its uncertainty is honest: the NEES (normalised estimation error squared, eᵀ P⁻¹ e) has a mean close to the ideal 6 and stays inside the 95 % chi-square band. A filter that is merely confident fails this test; the linear KF does.
  • During the 5 s dropout the error grows smoothly to 0.74 m and is back under 0.5 m at the first fix after it returns.

Without the dropout (the acceptance case in tests/test_acceptance.py) the EKF reaches 0.215 m RMSE. Its NEES fraction for seed 0 alone is 87.5 %; over seeds 0–7 it ranges from 82 % to 99 % and averages 93.6 % with mean NEES 6.07, which is why the consistency test pools seeds 0–4 instead of tuning the filter to one realisation.

Quick start

uv sync --all-groups
uv run dronefuse run --scenario figure8 --estimator all --seed 0 --dropout 30:35
# prints the metrics table; writes hero_figure8.png, errors_ekf.png, errors_kf.png, nees.png to out/
uv run dronefuse sweep --knob ekf.gyro_noise_std --values 1,2,4 --scale --seeds 0,1,2
# reruns with one knob scaled, averaged over seeds; writes out/sweep_ekf.gyro_noise_std.md
uv run pytest

Scenarios: hover, line, figure8. Estimators: dr, kf, ekf, all. Sweep knobs are sensor.*, init.*, kf.*, ekf.* config fields.

What is modelled

Estimation loop: scenario, sensor simulator, predict/update loop, estimate, metrics

Truth. A scripted path with closed-form position, velocity and acceleration (hover, straight line, or a 10 m × 5 m figure-eight with 30 s period at ~2 m/s). Yaw follows the horizontal velocity; roll and pitch are zero. No physics engine, no controller.

Sensors (seeded, so every estimator sees the same log):

Sensor Rate Model
Accelerometer 200 Hz specific force a_m = R(q)ᵀ (a − g) + b_a + n_a, reads [0, 0, +9.81] at rest; white noise 0.05 m/s², bias random walk
Gyroscope 200 Hz ω_m = ω + b_g + n_g; white noise 0.002 rad/s, bias random walk
Position fix 5 Hz z = p + n, 0.3 m per axis; optional dropout intervals

Conventions. World frame z-up, g = [0, 0, −9.81]. Quaternions (w, x, y, z), Hamilton product, q maps body → world. Attitude error is local: q_true = q ⊗ Exp(δθ) (Solà 2017).

The three estimators

All three implement predict(imu, dt) / update(fix) / estimate and run over the same log.

  1. Dead reckoning integrates the IMU and ignores fixes. Biases integrate into metres within seconds.

  2. Linear KF uses a constant-velocity model on [p, v] with white-noise acceleration and sees only the fixes. It lags in turns and cannot predict through a dropout.

  3. Error-state EKF keeps a nominal state x = [p, v, q, b_a, b_g] and a 15-dimensional error state δx = [δp, δv, δθ, δb_a, δb_g]. Every IMU sample propagates

    p ← p + v Δt + ½ (R(q)(a_m − b_a) + g) Δt²
    v ← v + (R(q)(a_m − b_a) + g) Δt
    q ← q ⊗ Exp((ω_m − b_g) Δt)          biases constant
    P ← F P Fᵀ + Q
    

    with F the error-state Jacobian (Solà eq. 270, checked against finite differences in the tests) and Q from the IMU white-noise and bias-walk densities. Each fix is a linear measurement of δp: Kalman gain in Joseph form, δx = K (z − p), inject into the nominal state, reset the attitude covariance.

The EKF's Q, R and P0 are built from the simulator's own noise numbers. That is the honest choice for a simulation study and is what makes the consistency test meaningful.

EKF position error per axis with ±3σ band

NEES of EKF and KF against the 95 % chi-square interval

Not modelled

Magnetometer, barometer or airspeed; vehicle dynamics, aerodynamics or a controller; IMU scale factors, misalignment, lever arm and time offsets; Earth rotation; fix outliers; real-time constraints. Yaw is observable only through horizontal acceleration, so on hover the yaw uncertainty grows, which is correct. Integration is first order with the IMU sample held over the 5 ms step.

Layout

dronefuse/
  scenario.py          analytic truth: Hover, Line, FigureEight
  sensors.py           SensorConfig, seeded IMU + position-fix simulator
  simulate.py          truth sampling, sensor log, run_estimator loop
  quaternion.py        Exp/Log, Hamilton product, rotation matrix
  estimators/
    base.py            Estimate, InitialState, Estimator protocol
    kinematics.py      strapdown step shared by DR and EKF
    linalg.py          Joseph-form Kalman update
    dead_reckoning.py  kf.py  ekf.py
  metrics.py           RMSE, NEES, chi-square bounds, dropout recovery
  pipeline.py          scenario → sensors → estimators → metrics
  sweep.py             parameter sweeps with per-filter overrides
  plots.py  cli.py
tests/                 unit tests per module + SPEC §4 acceptance tests
notebooks/walkthrough  raw sensors → DR drift → KF → EKF, step by step

numpy + scipy + matplotlib only; the full run takes about 3 s.

About

Error-state EKF fusing a 200 Hz IMU with 5 Hz position fixes for a simulated quadrotor, validated against dead reckoning and a linear KF (NEES-consistent)

Resources

Stars

2 stars

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages