Conversation
… minimum, not 0 W With no plan, the deadline reserve held a car to its own maximum with LimitPower(st, st.AllowedStepsW). Without a step table there was no lowest step to keep, so a 3,680 W plug-in hybrid on a 4,140-11,040 W charger got 3,680-3,680 W, and SnapChargeW returned 0 because max < min. The plan path gets PlanningSteps' ladder and already orders 4,140 W. LimitPower now keeps the charger's minimum as that one step when there are no steps, so the reserve orders what the plan orders and the car takes what it can. Tests fail on master 16c4ad0: LimitPower and DeadlineNeed, the reserve through SlotDirectiveAt (11 and 22 kW chargers), the controller's order, and two field-matrix rows with a new use, noplan (0 W, idle 55 min on master; 2.3 kWh in 1 h here). The known list is unchanged. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Codex Review SummaryThis comment shows the latest Codex review activity on this pull request.
ℹ️ About Codex in GitHubYour team has set up Codex to review pull requests in this repo. Reviews are triggered when you
Codex reacts with 👀 while any review is running, comments if it has suggestions, and reacts with 👍 once all reviews finish with no findings. |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Problem
With no plan (planner down or stale), Core runs a saved goal on its deadline reserve. On a charger without a step table, the reserve gave a car whose own maximum is below the charger's minimum an order of 0 W. Example: a plug-in hybrid with
max_w3,680 W on an 11 or 22 kW charger whose minimum is 4,140 W. The car stood still until a plan came back. Chargers with a step table were fine.An independent review of #1806 found it on 22 Oct 2026. The bug predates that PR. It hits any car with a known maximum, not only cars marked one-phase.
Cause
withDeadlineReserve(mpc/deadline_directive.go) takes its on-power fromDeadlineNeed, which holds it to the car withLimitPower(st, st.AllowedStepsW). When the car's maximum is below the charger's lowest step,LimitPowerkeeps that one step. Without a table it had no step to keep, so it returned 3,680–3,680 W.SnapChargeW(…, min 4140, max 3680, nil)then returns 0, because max < min.The plan path never hits this.
PlanningLimitspassesPlanningSteps, whose ladder starts at 4,140 W, soLimitPowerkeeps 4,140 W and the plan orders it.Fix
LimitPower: without steps, the charger's minimum is the one step it keeps, so the maximum is never below it. The reserve now orders 4,140 W, as the plan does, and the car takes what it can. This follows the owner's rule that Charge now and planned charging just run: Core never sends 0 W because the car's own maximum is lower. Nothing changes when a table exists or when the car's maximum reaches the charger's minimum.Evidence
Each new test fails on master 16c4ad0 and passes here:
loadpoint:TestLimitPowerKeepsTheChargersLowestStepandTestDeadlineNeedHoldsToTheCaradd the stepless 3.7 kW car. On master: power 3680–3680, want 4140.mpc:TestGoalReserveGivesASmallCarTheChargersMinimumgoes throughSlotDirectiveAtwith no plan, for 11,040 W and 22,080 W chargers. On master:LoadpointMaxPowerW: 0,LoadpointEnergyWh: 0.control:TestJoinedNoPlanGoalSmallCarGetsChargerMinimumruns the reserve through the controller to the driver order. On master: orders[0]. Here: 4,140 W.noplan, adds a saved goal, no plan, and the session car's maximum bound asinternal/carsbinds it. Two rows run the home box site (3 × 16 A, phase mode unset, no table, 4,140–11,000 W) with a one-phase car of 3,680 W,fast2sandeasee40s. On master both failidle: offer 0 W (EV deadline reserve), 0.0 kWh in 1 h, idle with room for 55m37s. Here both pass with 2.3 kWh, and the known list is unchanged. Peak phase is 20.0 A during the kettle step, the same as Charge now on that site.go vet ./internal/... ./cmd/ftw/...andgo test ./internal/... ./cmd/ftw/...pass on ed675d7, 60 packages. The matrix has 342 cases and 29 failing rows, the same 29 as on master.Limits
CarPhases == 1), as the fix(loadpoint): plan a one-phase car above the charger's minimum, not at it #1806 notes say. The controller orders three times the reserve, within the charger's maximum, so such a car draws its full current on its phase. Fuse protection stays with the site meter's measured current per phase. Before this fix, the same car got 0 W from the reserve.🤖 Generated with Claude Code